1
Perioada de actualizare
de la 15.11.2024 15:00
până la 20.11.2024 12:00
2
Propunerea ofertelor
de la 20.11.2024 12:00
până la 25.11.2024 11:00
au rămas 3 zile
3
Licitaţie
26.11.2024 10:51
4
Evaluare
5
Ofertele au fost evaluate
Statut Activ
Valoarea estimată fără TVA 66 666,67 MDL
Perioada clarificărilor: 15 nov 2024, 15:00 - 20 nov 2024, 12:00
Perioada de depunere a ofertelor: 20 nov 2024, 12:00 - 25 nov 2024, 11:00
Începutul licitației: 26 nov 2024, 10:51

Suport Tehnic pentru furnizori:

(+373) 79999801

Publicați oferta
Hx2 two-line POTS telephone for use with analog phone lines
Send-to-Caller Processing: High-pass Filter, Frequency Shifter, AGC/Limiter, Sample Rate Conversion (with AES option).
Analog Inputs
Send Analog Inputs: 2 for Hx2 (one per hybrid)
Connector : XLR Female, Pin 2 High (Active Balanced with RF Protection)
Input Range: Selectable between MIC and LINE levels
Line Input Level: Adjustable from -10dBV to +8 dBu (nominal)
Analog Clip Point : +21 dBu
Impedance: Bridging, > 50 Ohms
Analog-to-Digital Converter Resolution: 24 bits
Analog Outputs
Receive Analog Outputs: 1 for Hx1, 2 for Hx2 (one per hybrid)
Connector: XLR Male, Pin 3 High (Active Balanced, RF suppressed
Output Level: Nominal +4 dBu, fixed
Impedance: < 50 Ohms
Digital-to-Analog Converter Resolution: 24 bits
Headroom Before Clipping: 20 dB headroom above 4 dBU nominal levels
AES3 Digital Inputs/Outputs (optional)
Plug-in module converts standard analog XLR inputs and outputs to AES3 (one input or output on left channel of AES stream)
Conforms to AES3 standard
Sample rates: 32kHz to 48kHz.
Rate conversion: Input and output, independently selectable
Output Clock: AES input or 48kHz internal.
Input Level: Nominal at -20 dBFs.
Output Level: Nominal at -20 dBFs
Audio Performance
Frequency Response: 200 to 3400 Hz, +/- 1 dB
THD+N: < 0.5% THD+N using 1 KHz sine wave
Dynamic Range: Analog in to Analog out, studio loop mode, 10Hz-20Khz. A-weighted: > 92 dB
SNR: Analog output, referred to -12dBm phone line signal (+4dBu studio out), 10Hz-20Khz a-weighted: > 72 dB
Trans-Hybrid Loss: Analog phone line with ducking, gate, AGC, EQ
all OFF relative to +4dBu input level: >55 dB
Analog Telephone Line Connectivity
Universal interface for worldwide application. Programmable loop current, ring signaling, and flash time. Includes caller ID decoding using Bellcore 212 modem standard.
Power Supply
Type: Internal auto-ranging, 90–265 VAC auto-switching, 50–60 Hz.
Power consumption: 100 Watts.
Garantie minim 12 luni.
(Similar Telos Hx2 Digital Hybrids)
Informaţia despre solicitant
Codul fiscal/IDNO
Adresa
2028, MOLDOVA, mun.Chişinău, mun.Chişinău, strada Miorița 1
Web site
---
Persoana de contact
Nume Prenume
Natalia Braga
Telefonul de contact
068482641
Datele achizitiei
Data publicării
15 nov 2024, 14:30
Data ultimilor modificări
15 nov 2024, 15:00
Valoarea estimată (fără TVA)
66 666,67 MDL
Pasul minim de micşorare a ratei de licitaţie
666,67 MDL
Achizitii.md ID
21311669
Tipul procedurii
Cererea ofertelor de prețuri (bunuri)
Criteriu de atribuire
Preţul cel mai scăzut
Adresa de livrare
2028, MOLDOVA, mun.Chişinău, mun.Chişinău, strada Miorița 1
Durata contractului
9 dec 2024 14:33 - 30 ian 2025 14:56
Lista pozițiilor
1)
Denumirea
Lotul nr. 7 Hibrid telephone -Hx2 two-line POTS telephone for use with analog phone lines Send-to-Caller Processing: High-pass Filter, Frequency Shifter, AGC/Limiter, Sample Rate Conversion (with AES option). Analog Inputs Send Analog Inputs: 2 for Hx2 (one per hybrid) Connector : XLR Female, Pin 2 High (Active Balanced with RF Protection) Input Range: Selectable between MIC and LINE levels Line Input Level: Adjustable from -10dBV to +8 dBu (nominal) Analog Clip Point : +21 dBu Impedance: Bridging, > 50 Ohms Analog-to-Digital Converter Resolution: 24 bits Analog Outputs Receive Analog Outputs: 1 for Hx1, 2 for Hx2 (one per hybrid) Connector: XLR Male, Pin 3 High (Active Balanced, RF suppressed Output Level: Nominal +4 dBu, fixed Impedance: < 50 Ohms Digital-to-Analog Converter Resolution: 24 bits Headroom Before Clipping: 20 dB headroom above 4 dBU nominal levels AES3 Digital Inputs/Outputs (optional) Plug-in module converts standard analog XLR inputs and outputs to AES3 (one input or output on left channel of AES stream) Conforms to AES3 standard Sample rates: 32kHz to 48kHz. Rate conversion: Input and output, independently selectable Output Clock: AES input or 48kHz internal. Input Level: Nominal at -20 dBFs. Output Level: Nominal at -20 dBFs Audio Performance Frequency Response: 200 to 3400 Hz, +/- 1 dB THD+N: < 0.5% THD+N using 1 KHz sine wave Dynamic Range: Analog in to Analog out, studio loop mode, 10Hz-20Khz. A-weighted: > 92 dB SNR: Analog output, referred to -12dBm phone line signal (+4dBu studio out), 10Hz-20Khz a-weighted: > 72 dB Trans-Hybrid Loss: Analog phone line with ducking, gate, AGC, EQ all OFF relative to +4dBu input level: >55 dB Analog Telephone Line Connectivity Universal interface for worldwide application. Programmable loop current, ring signaling, and flash time. Includes caller ID decoding using Bellcore 212 modem standard. Power Supply Type: Internal auto-ranging, 90–265 VAC auto-switching, 50–60 Hz. Power consumption: 100 Watts. Garantie minim 12 luni. (Similar Telos Hx2 Digital Hybrids) CPV: 32300000-6 - Receptoare de televiziune şi de radio şi aparate de înregistrare sau de redare a sunetului sau a imaginii
Cantitatea: 2.0
Unități de măsură: Bucata
Documentele procedurii de achiziție
declarația beneficiarilor efectivi.doc
Documentele la ofertă
declarația beneficiarilor efectivi.doc
15.11.24 15:00
duae.docx
Documentele la ofertă
duae.docx
15.11.24 15:00
anunt de participare echipament audio.semnat.pdf anunt de participare echipament audio.semnat.pdf
Documentele la ofertă
anunt de participare echipament audio.semnat.pdf
15.11.24 15:00
anexele la documentatia standard.docx
Documentele la ofertă
anexele la documentatia standard.docx
15.11.24 15:00
Cu părere de rău întrebările se pun doar în perioada "Activ".
Clarificări