Select the type of procedure
1
Enquiry period
with
03.08.2026 09:25
to 14.08.2026 12:46
to 14.08.2026 12:46
2
Bidding period
with
14.08.2026 12:46
to 05.09.2026 10:46
to 05.09.2026 10:46
12 days left
3
Auction
will not be used
4
Evaluation
5
Contract
Status
Bidding period
Estimated value without VAT
1 226 164 MDL
Period of clarifications:
3 Aug 2026, 9:25 - 14 Aug 2026, 12:46
Submission of proposals:
14 Aug 2026, 12:46 - 5 Sep 2026, 10:46
Supplier technical support:
(+373) 79999801
This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.
Subscribe impossible
during the period Bidding period
conform anuntului de participare
Information about customer
Fiscal code/IDNO
Address
MD2004, MOLDOVA, mun.Chişinău, mun.Chişinău, bd. Ștefan cel Mare 165
Web site
---
The contact person
Purchase data
Date created
3 Aug 2026, 9:25
Date modified
12 Aug 2026, 12:46
Achizitii.md ID
21662588
MTender ID
CPV
33100000-1 - Echipamente medicale
Type of procedure
Open tender
Award criteria
The lowest price
Funding sources
List of lots
Lot nr. 11 - Baie ultrasonică digital cu incalzire Bandelin Sonorix Digitec DT
Budget: 28000.0 MDL
Active
Lot nr. 12 - Sistem medical avansat pentru analiza compoziției corporale prin bioimpedanță multifrecvență
Budget: 240000.0 MDL
Active
Lot nr. 13 - Calorimetrie indirectă pentru determinarea precisă a metabolismului bazal REE și RQ
Budget: 600000.0 MDL
Active
Documents of the procurement procedure
ds bunuri_servicii.docx
Documents history
-
ds bunuri_servicii.docx
ID: 7a3f61ef-7740-49cd-8940-da926d495860
Bidding Documents
-
ds bunuri_servicii.docx
ID: 7a3f61ef-7740-49cd-8940-da926d495860
Bidding Documents
-
ds bunuri_servicii.docx
ID: 7a3f61ef-7740-49cd-8940-da926d495860
Bidding Documents
Bidding Documents
-documentatia standart
12.08.26 12:46
anexa nr. 2 anunț de participare.docx
Documents history
-
anexa nr. 2 anunț de participare.docx
ID: dcd6f5dc-2fd1-4c68-adaf-e0c8e4ba916a
Bidding Documents
-
anexa nr. 2 anunț de participare.docx
ID: dcd6f5dc-2fd1-4c68-adaf-e0c8e4ba916a
Bidding Documents
-
anexa nr. 2 anunț de participare.docx
ID: dcd6f5dc-2fd1-4c68-adaf-e0c8e4ba916a
Bidding Documents
Bidding Documents
-anunt de participare
12.08.26 12:46
Baie ultrasonică digital cu incalzire Bandelin Sonorix Digitec DT
Date:
3 Aug 2026, 12:20
Question's name:
lot 11. Baie ultrasonică digital cu incalzire Bandelin Sonorix Digitec DT
Question:
Buna ziua.
Se va accepta Baie ultrasonică digital cu incalzire cu dimensiuni interioare 300 × 150 × 100 mm
si dimensiuni exterioare 330 × 180 × 230 mm ?
Multumesc.
Answer (4 Aug 2026, 09:28):
Buna ziua
Va rugam sa respectati cerintele autoritatii contractante
O zi buna
Reciclator bactericid cu raze ultraviolete
Date:
10 Aug 2026, 19:16
Question's name:
Dovezi calitate
Question:
Buna ziua, nu am vazut, se cer dovezi calitate exprimate prin cercetări de laborator privind eficienta utilajului la viruși, bacterii si micuțe? Daca da va rugam sa introduceti in calificative, va multumim
Answer (12 Aug 2026, 10:14):
Autoritatea contractantă vă mulțumește pentru interesul manifestat și pentru sugestia dumneavoastră. și vă asigurăm că specificațiile tehnice actuale din Caietul de Sarcini sunt extrem de riguroase și au fost stabilite tocmai pentru a garanta achiziția unui echipament de înaltă calitate medicală și profesională. Parametrii solicitați — cum ar fi structura din oțel inoxidabil, performanța lămpilor de minimum 10.800 ore de funcționare, debitul motorului de 200 m³/h și obligativitatea certificării conform standardului de siguranță medicală GOST 12.2.025-76 (clasa 1 tip N) — constituie criterii tehnice obligatorii și eliminatorii.În etapa de evaluare, Comisia va verifica cu strictețe ca toți acești parametri să fie demonstrați prin documentele oficiale ale producătorului (fișe tehnice, manuale, certificate). Orice ofertă care nu va demonstra îndeplinirea exactă a acestor standarde de calitate va fi declarată neconformă și va fi respinsă.”
Date:
11 Aug 2026, 16:55
Question's name:
Calorimetrie indirectă pentru determinarea precisă a metabolismului bazal REE și RQ
Question:
Buna ziua. Cerintele tehnice nu prevad o serie de accesorii care sunt necesare unor astfel de echipamente , cum ar fi de exemplu filtrele sau circuite etc. Trebuie acestea incluse in setul de livrare sau nu? In caz ca da, va rugam sa indicati niste cantitati estimative.
Answer (12 Aug 2026, 12:40):
Accesorii incluse: Kit Canopy, set de măști din silicon (minimum 2 dimensiuni), seringă de calibrare, kit de calibrare cu gaz (regulator și butelie de gaz)
Echipamentul trebuie livrat ca un sistem complet, gata de utilizare, cu toate accesoriile necesare și o rezervă inițială de consumabile pentru ambele grupuri de pacienți, cuprinzând:
1 bucată Kit Glugă Canopy (dimensiune mare)
50 bucăți de Văluri de unică folosință pentru Glugă Canopy dimensiune mare
2 bucăți de mască facială din silicon (dimensiuni diferite) cu 1 calotă de fixare pe cap și 1 debitmetru extern
50 bucăți de Filtre Antibacteriene/Antivirale cu piesă bucală rotundă
100 bucăți de Linii de prelevare probe (Sampling Lines) pentru subiecți cu respirație spontană.
Pentru pacienții ventilați mecanic, sistemul trebuie să includă:
50 bucăți de senzori de debit de unică folosință flow-ree
50 bucăți de Pachete de prelevare probe de gaz ICU (ICU Gas Sampling Packs)
50 bucăți de Filtre Antibacteriene/Antivirale VENT HME
50 bucăți de Filtre Antibacteriene/Antivirale VENT.
1 bucată seringă de calibrare de 3 litri
1 bucată kit de calibrare cu gaz cuprinzând
1 bucată de Regulator MET Mix cu un ansamblu de furtun ISO5359,
1 bucată de butelie de Gaz de Calibrare Amestec Metabolic (cuprinzând un amestec certificat de 16% O2, 5% CO2 și balanță de N2)
1 bucată de cărucior medical mobil dedicat, cu suport de monitor integrat și 1 bucată de suport pentru butelia de gaz.
Date:
12 Aug 2026, 11:42
Question's name:
Concretizat recirculatoare
Question:
Buna ziua ,specificați va rog încăperile pentru care vor fi destinate, va multumim
Answer (12 Aug 2026, 16:58):
Buna ziua
Date:
12 Aug 2026, 13:56
Question's name:
Calorimetrie indirectă pentru determinarea precisă a metabolismului bazal REE și RQ
Question:
In urma analizei caietului de sarcini, constatatam o incompatibilitate tehnica intre cerintele solicitate cumulativ, care face caietul de sarcini imposibil de indeplinit de catre orice producator de pe piata:
1. Incompatibilitate senzori si operare: Se solicita un "Senzor O2 paramagnetic". Aceasta tehnologie constructiva este specifica sistemelor stationare mari, care necesita in mod obligatoriu un timp de preincalzire a senzorilor (warm-up) si calibrare frecventa. Simultan, se solicita "Pornire instantanee", "Calibrare automata cu aer ambiental (cu gaz o data pe luna)" si "Ecran tactil integrat". Aceste dotari sunt specifice exclusiv platformelor clinice compacte de noua generatie, care folosesc senzori de O2 digitali (nu paramagnetici). Senzorii paramagnetici nu pot functiona fizic instantaneu (no warm-up) si nu permit calibrarea o singura data pe luna. Mentinerea ambelor cerinte restrictioneaza artificial concurenta, nicio tehnologie actuala neputand sa le indeplineasca simultan.
Va solicitam sa clarificati ce tip de aparat se doreste: fie un sistem cu senzor O2 paramagnetic (care nu permite pornirea instantanee si necesita calibrari frecvente), fie un sistem modern cu senzori de O2 digitali (care are capacitatea de pornire instantanee si necesita calibrare cu gaz, in medie, o singura data pe luna).
2. Totodata, avand in vedere cerintele de compactitate si calibrare simplificata specifice noilor platforme clinice, va rugam sa ne comunicati daca se accepta ca, in loc de sistemul de masurare "Breath-by-Breath", echipamentul ofertat sa utilizeze tehnologia moderna bazata pe "camera de amestec micro-dinamica".
Answer (12 Aug 2026, 16:58):
Un sistem de calorimetrie indirectă care utilizează metoda „camerei de amestec micro-dinamice” pentru determinarea precisă a metabolismului bazal (REE) și a coeficientului respirator (RQ), eliminând erorile majore generate de utilizarea formulelor predictive standard care nu pot surprinde variabilitatea metabolică individuală, oferind o imagine dinamică și exactă a oxidării substraturilor energetice (carbohidrați, lipide).
-Principiu și Validare Calorimetrie indirectă utilizând metoda „camerei de amestec micro-dinamice” pentru determinarea VO2, VCO2, REE și RQ
Validat clinic și științific prin studii de spectrometrie de masă.
-Senzori de gaz: senzor de O2, celulă de combustibil galvanică (GFC) și senzor de CO2 NDIR (infraroșu) cu auto-calibrare pentru eliminarea erorilor de derivă
-Interfețe de măsurare Sistem hibrid care include: Canopy/Glugă (diluție), Mască facială oronazală și kit pentru conectarea la un ventilator mecanic
-Operare eficientă și ușoară:
Pornire foarte rapidă (doar 5 minute de încălzire în timp ce subiectul este pregătit)
-Ecran tactil integrat
-Controlul calității. Calibrare automată cu aer ambiental la pornire, fără a fi necesară utilizarea zilnică a buteliei de gaz. Calibrarea cu gaz nu ar trebui să fie necesară mai des de o dată pe lună.
-Identificarea automată a stării de echilibru metabolic (Steady State) și afișarea în timp real a curbelor de stabilitate.
-Capacități analitice Calcul automat pentru: REE (kcal/zi), VO2, VCO2, RQ și rata de oxidare a substratului (Grăsimi, Carbohidrați, Proteine %)
-Mobilitate Dispozitiv compact (greutate < 5 kg), echipat cu baterie internă, autonomie min. 60 min
-Platformă software completă de gestionare a datelor inclusă, conformă cu GDPR, cu funcții de export în formate editabile (XLS, XML) și PDF.
-Pachetul software trebuie să includă 1 aplicație media pentru baza de date principală (master database), 1 modul software pentru achiziția de date metabolice în timpul ventilației mecanice, 1 modul software pentru testarea metabolică cu glugă canopy și 1 modul software pentru testarea metabolică cu mască facială.
2)
-Conectivitatea trebuie să includă USB nativ și Bluetooth.
Date:
12 Aug 2026, 13:58
Question's name:
Calorimetrie indirectă pentru determinarea precisă a metabolismului bazal REE și RQ
Question:
Va rugam sa ne comunicati daca se accepta platforme cu conectivitate USB si Bluetooth, fara LAN.
Answer (12 Aug 2026, 16:58):
Un sistem de calorimetrie indirectă care utilizează metoda „camerei de amestec micro-dinamice” pentru determinarea precisă a metabolismului bazal (REE) și a coeficientului respirator (RQ), eliminând erorile majore generate de utilizarea formulelor predictive standard care nu pot surprinde variabilitatea metabolică individuală, oferind o imagine dinamică și exactă a oxidării substraturilor energetice (carbohidrați, lipide).
-Principiu și Validare Calorimetrie indirectă utilizând metoda „camerei de amestec micro-dinamice” pentru determinarea VO2, VCO2, REE și RQ
Validat clinic și științific prin studii de spectrometrie de masă.
-Senzori de gaz: senzor de O2, celulă de combustibil galvanică (GFC) și senzor de CO2 NDIR (infraroșu) cu auto-calibrare pentru eliminarea erorilor de derivă
-Interfețe de măsurare Sistem hibrid care include: Canopy/Glugă (diluție), Mască facială oronazală și kit pentru conectarea la un ventilator mecanic
-Operare eficientă și ușoară:
Pornire foarte rapidă (doar 5 minute de încălzire în timp ce subiectul este pregătit)
-Ecran tactil integrat
-Controlul calității. Calibrare automată cu aer ambiental la pornire, fără a fi necesară utilizarea zilnică a buteliei de gaz. Calibrarea cu gaz nu ar trebui să fie necesară mai des de o dată pe lună.
-Identificarea automată a stării de echilibru metabolic (Steady State) și afișarea în timp real a curbelor de stabilitate.
-Capacități analitice Calcul automat pentru: REE (kcal/zi), VO2, VCO2, RQ și rata de oxidare a substratului (Grăsimi, Carbohidrați, Proteine %)
-Mobilitate Dispozitiv compact (greutate < 5 kg), echipat cu baterie internă, autonomie min. 60 min
-Platformă software completă de gestionare a datelor inclusă, conformă cu GDPR, cu funcții de export în formate editabile (XLS, XML) și PDF.
-Pachetul software trebuie să includă 1 aplicație media pentru baza de date principală (master database), 1 modul software pentru achiziția de date metabolice în timpul ventilației mecanice, 1 modul software pentru testarea metabolică cu glugă canopy și 1 modul software pentru testarea metabolică cu mască facială.
2)
-Conectivitatea trebuie să includă USB nativ și Bluetooth.