Public procurement
21560079
Testări fizico-radiologice a dispozitivelor cu radiații ionizante
1
Enquiry period
with 03.02.2026 11:05
to 05.02.2026 10:00
to 05.02.2026 10:00
2
Bidding period
with 05.02.2026 10:00
to 10.02.2026 10:00
to 10.02.2026 10:00
4 days left
3
Auction
4
Evaluation
5
Bids have been evaluated
Status
Active
Estimated value without VAT
102 000 MDL
Period of clarifications:
3 Feb 2026, 11:05 - 5 Feb 2026, 10:00
Submission of proposals:
5 Feb 2026, 10:00 - 10 Feb 2026, 10:00
Auction start date:
will not be used
Supplier technical support:
(+373) 79999801
This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.
RD05-4: În fizică,
LA07-1: Pentru radiologie de diagnosticare
Testari fizico-radiologice de performanță a
generatoarelor cu Raze X, inclusiv:
Tensiunea tubului(kV) - Acurateţea tensiunii tubului)
Timpul de expunere(t) - Acurateţea timpului de expunere
Puterea de ieşire (Y) tubului de Raze-X, inclusiv:
- Reproducerea si linearitatea mAs
- Constanţa puterii de ieșire în mGy/mAs pentru o serie de
valori mA și/sau mAs;
Grosimeа de semiatenuare (HVL)/Filtrarea totală - HVL
sau Filtrarea totală (în diapazonul kV stabilit);
Dozimetrie, inclusiv
- Calibrarea indicatorului de doză incorporat (Acurateţea
DAP/KAP-metru, daca este dotat);
- Calculul si estimarea incertitudinii totale DAP/KAP-metru
incorporat;
- si/sau Calculul şi evaluarea/estimarea (sisteme fără
DAP/KAP) valorilor tipice a dozelor de expunere a pacienţilor
(în cazul radiografiei pentru stabilirea Nivelului de referință
pentru diagnostic(DRL) este recomandat: Kae-Kerma
aeriană la suprafață de intrare sau Pka-Produsul Kerma
aeriană–suprafață)
- radiația de scurgere(unde este practicabil)
-Doza absorbită suprafața de intrare pe procedura (nivelele
de referință elaborate de Beneficiar (mGy) sau APR
* Pentru CT: CTDI pentru fiecare tip de scanare si FOV
(Body&Head)
Acuratetea DAP
Linearitatea ROI
Standarde de referință
RP 162. Criteria for Acceptability of Medical Radiological
Equipment used in Diagnostic Radiology, Nuclear Medicine
and Radiotherapy. Radiation Protection No162. European
Commission. European Union, 2012
IAEA Technical Reports Series No. 457. Dosimetry in
Diagnostic Radiology: An International Code of Practice.
IAEA, Vienna, 2007
IAEA Human Health Series No. 24. Dosimetry in
Diagnostic Radiology for Paediatric Patients. IAEA, Vienna,
2013
IAEA Human Health Series 4. Implementation of the
International Code of Practice on Dosimetry in Diagnostic
Radiology. IAEA, 2011
ICRU Report 74. Patient Dosimetry for X Rays Used in
Medical Imaging. Oxford University Press. 2005
ICRP Publication 135. Diagnostic Reference Levels in
Medical Imaging. Ann. ICRP 46(1). 2017
Graficul prestare servicii – pe parcursul anului 2026
LA07-1: Pentru radiologie de diagnosticare
Testari fizico-radiologice de performanță a
generatoarelor cu Raze X, inclusiv:
Tensiunea tubului(kV) - Acurateţea tensiunii tubului)
Timpul de expunere(t) - Acurateţea timpului de expunere
Puterea de ieşire (Y) tubului de Raze-X, inclusiv:
- Reproducerea si linearitatea mAs
- Constanţa puterii de ieșire în mGy/mAs pentru o serie de
valori mA și/sau mAs;
Grosimeа de semiatenuare (HVL)/Filtrarea totală - HVL
sau Filtrarea totală (în diapazonul kV stabilit);
Dozimetrie, inclusiv
- Calibrarea indicatorului de doză incorporat (Acurateţea
DAP/KAP-metru, daca este dotat);
- Calculul si estimarea incertitudinii totale DAP/KAP-metru
incorporat;
- si/sau Calculul şi evaluarea/estimarea (sisteme fără
DAP/KAP) valorilor tipice a dozelor de expunere a pacienţilor
(în cazul radiografiei pentru stabilirea Nivelului de referință
pentru diagnostic(DRL) este recomandat: Kae-Kerma
aeriană la suprafață de intrare sau Pka-Produsul Kerma
aeriană–suprafață)
- radiația de scurgere(unde este practicabil)
-Doza absorbită suprafața de intrare pe procedura (nivelele
de referință elaborate de Beneficiar (mGy) sau APR
* Pentru CT: CTDI pentru fiecare tip de scanare si FOV
(Body&Head)
Acuratetea DAP
Linearitatea ROI
Standarde de referință
RP 162. Criteria for Acceptability of Medical Radiological
Equipment used in Diagnostic Radiology, Nuclear Medicine
and Radiotherapy. Radiation Protection No162. European
Commission. European Union, 2012
IAEA Technical Reports Series No. 457. Dosimetry in
Diagnostic Radiology: An International Code of Practice.
IAEA, Vienna, 2007
IAEA Human Health Series No. 24. Dosimetry in
Diagnostic Radiology for Paediatric Patients. IAEA, Vienna,
2013
IAEA Human Health Series 4. Implementation of the
International Code of Practice on Dosimetry in Diagnostic
Radiology. IAEA, 2011
ICRU Report 74. Patient Dosimetry for X Rays Used in
Medical Imaging. Oxford University Press. 2005
ICRP Publication 135. Diagnostic Reference Levels in
Medical Imaging. Ann. ICRP 46(1). 2017
Graficul prestare servicii – pe parcursul anului 2026
Information about customer
Fiscal code/IDNO
Address
MD 2004, MOLDOVA, mun.Chişinău, mun.Chişinău, str.Toma Ciorbă, 1
Web site
---
The contact person
Full name
Serviciul achizitii publice
Contact phone
022250809, 022250707
E-mail
Purchase data
Date created
3 Feb 2026, 10:58
Date modified
3 Feb 2026, 16:54
Estimated value (without VAT)
102 000 MDL
Achizitii.md ID
21560079
MTender ID
Type of procedure
Low cost purchase
Award criteria
The lowest price
Delivery address
MD 2004, MOLDOVA, mun.Chişinău, mun.Chişinău, str.Toma Ciorbă, 1
Contract period
17 Feb 2026 02:00 - 30 Dec 2026 02:00
List of positions
1)
Title
Quantity: 1.0
Unit of measurement: Bucata
2)
Title
Quantity: 1.0
Unit of measurement: Bucata
3)
Title
Quantity: 1.0
Unit of measurement: Bucata
4)
Title
Quantity: 1.0
Unit of measurement: Bucata
5)
Title
Quantity: 1.0
Unit of measurement: Bucata
6)
Title
Quantity: 1.0
Unit of measurement: Bucata
7)
Title
Quantity: 1.0
Unit of measurement: Bucata
8)
Title
Quantity: 1.0
Unit of measurement: Bucata
9)
Title
Quantity: 1.0
Unit of measurement: Bucata
10)
Title
Quantity: 1.0
Unit of measurement: Bucata
11)
Title
Quantity: 1.0
Unit of measurement: Bucata
12)
Title
Quantity: 1.0
Unit of measurement: Bucata
13)
Title
Quantity: 1.0
Unit of measurement: Bucata
14)
Title
Quantity: 1.0
Unit of measurement: Bucata
15)
Title
Quantity: 7.0
Unit of measurement: Bucata
16)
Title
Quantity: 3.0
Unit of measurement: Bucata
17)
Title
Quantity: 1.0
Unit of measurement: Bucata
18)
Title
Quantity: 1.0
Unit of measurement: Bucata
Subscription settings saved.
Remember, you can always go back to the Subscriptions section and make changes to the frequency of receiving letters, delete or add categories and customers.
Вы уже подписаны на данный CPV код
Insufficient funds
You do not have enough funds in your account to set up a subscription. Top up your account, to continue.
Subscription Setup
Subscribe to daily email notifications according to selected CPV and/or IDNO categories for the period:
The subscription cost is 10 MDL with VAT per month.
View Regulations.
Documents of the procurement procedure
21560079 anunt de participare testări fizico-radiologice.pdf
21560079 anunt de participare testări fizico-radiologice.pdf
Documents history
-
21560079 anunt de participare testări fizico-radiologice.pdf
21560079 anunt de participare testări fizico-radiologice.pdf
ID: 6eb5c205-4186-4850-84d2-28b99731e62f
Bidding Documents
-
1. anunt de participare 2026 testari fizico-radiologice.docx
ID: 6eb5c205-4186-4850-84d2-28b99731e62f
Bidding Documents
Bidding Documents
-
3.02.26 16:54
Unfortunately, questions can be asked only during the "Active" period.
Clarifications
Document successfully signed
OK