1
Enquiry period
with 15.11.2024 15:00
to 20.11.2024 12:00
2
Bidding period
with 20.11.2024 12:00
to 25.11.2024 11:00
3 days left
3
Auction
26.11.2024 10:51
4
Evaluation
5
Bids have been evaluated
Status Active
Estimated value without VAT 66 666,67 MDL
Period of clarifications: 15 Nov 2024, 15:00 - 20 Nov 2024, 12:00
Submission of proposals: 20 Nov 2024, 12:00 - 25 Nov 2024, 11:00
Auction start date: 26 Nov 2024, 10:51

Supplier technical support:

(+373) 79999801

Submit offer
Hx2 two-line POTS telephone for use with analog phone lines
Send-to-Caller Processing: High-pass Filter, Frequency Shifter, AGC/Limiter, Sample Rate Conversion (with AES option).
Analog Inputs
Send Analog Inputs: 2 for Hx2 (one per hybrid)
Connector : XLR Female, Pin 2 High (Active Balanced with RF Protection)
Input Range: Selectable between MIC and LINE levels
Line Input Level: Adjustable from -10dBV to +8 dBu (nominal)
Analog Clip Point : +21 dBu
Impedance: Bridging, > 50 Ohms
Analog-to-Digital Converter Resolution: 24 bits
Analog Outputs
Receive Analog Outputs: 1 for Hx1, 2 for Hx2 (one per hybrid)
Connector: XLR Male, Pin 3 High (Active Balanced, RF suppressed
Output Level: Nominal +4 dBu, fixed
Impedance: < 50 Ohms
Digital-to-Analog Converter Resolution: 24 bits
Headroom Before Clipping: 20 dB headroom above 4 dBU nominal levels
AES3 Digital Inputs/Outputs (optional)
Plug-in module converts standard analog XLR inputs and outputs to AES3 (one input or output on left channel of AES stream)
Conforms to AES3 standard
Sample rates: 32kHz to 48kHz.
Rate conversion: Input and output, independently selectable
Output Clock: AES input or 48kHz internal.
Input Level: Nominal at -20 dBFs.
Output Level: Nominal at -20 dBFs
Audio Performance
Frequency Response: 200 to 3400 Hz, +/- 1 dB
THD+N: < 0.5% THD+N using 1 KHz sine wave
Dynamic Range: Analog in to Analog out, studio loop mode, 10Hz-20Khz. A-weighted: > 92 dB
SNR: Analog output, referred to -12dBm phone line signal (+4dBu studio out), 10Hz-20Khz a-weighted: > 72 dB
Trans-Hybrid Loss: Analog phone line with ducking, gate, AGC, EQ
all OFF relative to +4dBu input level: >55 dB
Analog Telephone Line Connectivity
Universal interface for worldwide application. Programmable loop current, ring signaling, and flash time. Includes caller ID decoding using Bellcore 212 modem standard.
Power Supply
Type: Internal auto-ranging, 90–265 VAC auto-switching, 50–60 Hz.
Power consumption: 100 Watts.
Garantie minim 12 luni.
(Similar Telos Hx2 Digital Hybrids)
Information about customer
Fiscal code/IDNO
Address
2028, MOLDOVA, mun.Chişinău, mun.Chişinău, strada Miorița 1
Web site
---
The contact person
Full name
Natalia Braga
Contact phone
068482641
Purchase data
Date created
15 Nov 2024, 14:30
Date modified
15 Nov 2024, 15:00
Estimated value (without VAT)
66 666,67 MDL
The minimum downward of the price
666,67 MDL
Achizitii.md ID
21311669
Type of procedure
Request price offers (goods)
Award criteria
The lowest price
Delivery address
2028, MOLDOVA, mun.Chişinău, mun.Chişinău, strada Miorița 1
Contract period
9 Dec 2024 14:33 - 30 Jan 2025 14:56
List of positions
1)
Title
Lotul nr. 7 Hibrid telephone -Hx2 two-line POTS telephone for use with analog phone lines Send-to-Caller Processing: High-pass Filter, Frequency Shifter, AGC/Limiter, Sample Rate Conversion (with AES option). Analog Inputs Send Analog Inputs: 2 for Hx2 (one per hybrid) Connector : XLR Female, Pin 2 High (Active Balanced with RF Protection) Input Range: Selectable between MIC and LINE levels Line Input Level: Adjustable from -10dBV to +8 dBu (nominal) Analog Clip Point : +21 dBu Impedance: Bridging, > 50 Ohms Analog-to-Digital Converter Resolution: 24 bits Analog Outputs Receive Analog Outputs: 1 for Hx1, 2 for Hx2 (one per hybrid) Connector: XLR Male, Pin 3 High (Active Balanced, RF suppressed Output Level: Nominal +4 dBu, fixed Impedance: < 50 Ohms Digital-to-Analog Converter Resolution: 24 bits Headroom Before Clipping: 20 dB headroom above 4 dBU nominal levels AES3 Digital Inputs/Outputs (optional) Plug-in module converts standard analog XLR inputs and outputs to AES3 (one input or output on left channel of AES stream) Conforms to AES3 standard Sample rates: 32kHz to 48kHz. Rate conversion: Input and output, independently selectable Output Clock: AES input or 48kHz internal. Input Level: Nominal at -20 dBFs. Output Level: Nominal at -20 dBFs Audio Performance Frequency Response: 200 to 3400 Hz, +/- 1 dB THD+N: < 0.5% THD+N using 1 KHz sine wave Dynamic Range: Analog in to Analog out, studio loop mode, 10Hz-20Khz. A-weighted: > 92 dB SNR: Analog output, referred to -12dBm phone line signal (+4dBu studio out), 10Hz-20Khz a-weighted: > 72 dB Trans-Hybrid Loss: Analog phone line with ducking, gate, AGC, EQ all OFF relative to +4dBu input level: >55 dB Analog Telephone Line Connectivity Universal interface for worldwide application. Programmable loop current, ring signaling, and flash time. Includes caller ID decoding using Bellcore 212 modem standard. Power Supply Type: Internal auto-ranging, 90–265 VAC auto-switching, 50–60 Hz. Power consumption: 100 Watts. Garantie minim 12 luni. (Similar Telos Hx2 Digital Hybrids) CPV: 32300000-6 - Television and radio receivers, and sound or video recording or reproducing apparatus
Quantity: 2.0
Unit of measurement: Bucata
Documents of the procurement procedure
declarația beneficiarilor efectivi.doc
Bidding Documents
declarația beneficiarilor efectivi.doc
15.11.24 15:00
duae.docx
Bidding Documents
duae.docx
15.11.24 15:00
anunt de participare echipament audio.semnat.pdf anunt de participare echipament audio.semnat.pdf
Bidding Documents
anunt de participare echipament audio.semnat.pdf
15.11.24 15:00
anexele la documentatia standard.docx
Bidding Documents
anexele la documentatia standard.docx
15.11.24 15:00
Unfortunately, questions can be asked only during the "Active" period.
Clarifications