Select the type of procedure
Commercial procurement
21242205
1
Enquiry period
with
24.06.2024 10:41
to 25.06.2024 14:00
to 25.06.2024 14:00
2
Bidding period
with
25.06.2024 14:00
to 29.06.2024 14:00
to 29.06.2024 14:00
3
Auction
will not be used
4
Evaluation
5
Contract
Status
Evaluation
Estimated value without VAT
321 450 MDL
Period of clarifications:
24 Jun 2024, 10:41 - 25 Jun 2024, 14:00
Submission of proposals:
25 Jun 2024, 14:00 - 29 Jun 2024, 14:00
Supplier technical support:
(+373) 79999801
This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.
Subscribe impossible
during the period Evaluation
Reamplasarea unui segment ade gazoduct
Information about customer
Title
Fiscal code/IDNO
Address
MD3909, MOLDOVA, Cahul, mun.Cahul, Piata Independentei, 2
Web site
---
The contact person
Purchase data
Date created
24 Jun 2024, 10:41
Date modified
25 Jun 2024, 8:44
Achizitii.md ID
21242205
MTender ID
CPV
45200000-9 - Lucrări de construcţii complete sau parţiale şi lucrări publice
Type of procedure
Low cost purchase
Award criteria
The lowest price
Funding sources
List of lots
Documents of the procurement procedure
Date:
25 Jun 2024, 08:44
Question's name:
caiet de sarcini
Question:
va rog ce fel de SDR ? PE ? in caiet de sarcini nu este inclus cablu, banda de avertizare
Answer (25 Jun 2024, 10:17):
Teava PE100 SDR11 -160x14.6, Fir trasor si banda de marcaj este inclusa in norma.
Date:
25 Jun 2024, 08:50
Question's name:
caiet de sarcini
Question:
la lungimea de 380 m.l d160 numa 10 imbinari ? ( cel puțin trebue 28 ) ?
Answer (25 Jun 2024, 10:18):
Imbinari prin sudura de tip electrofuziune intre teava si fiting ,da a fost o gresala
mecanica , este necesar de inclus in calcul 30 de imbinari.
Diferenta sau marja de calcul intre suma estimativa si ofertele este de -15% si +15%.
La evaluarea ofertelor nu va fi o problema.
Date:
25 Jun 2024, 08:51
Question's name:
caiet de sarcini
Question:
la lungimea de 380 m.l d160 aveți 10 imbinari ? ( cel puțin trebue 29 de imbinari )?
Answer (25 Jun 2024, 10:18):
Imbinari prin sudura de tip electrofuziune intre teava si fiting ,da a fost o gresala
mecanica , este necesar de inclus in calcul 30 de imbinari.
Diferenta sau marja de calcul intre suma estimativa si ofertele este de -15% si +15%.
La evaluarea ofertelor nu va fi o problema.
Date:
25 Jun 2024, 10:24
Question's name:
caiet de sarcini
Question:
Testarea gazoductului?(verificare la etansietate)?
Answer (25 Jun 2024, 10:28):
Includeți și testarea.
Date:
25 Jun 2024, 10:32
Question's name:
caiet de sarcini
Question:
gazoduct ce presiune ? la ce presiune verivicare ? MPa
Answer (25 Jun 2024, 10:36):
Presiune înaltă pînă la 3,0 MPa.
Date:
25 Jun 2024, 10:42
Question's name:
caiet de sarcini
Question:
tub de protectie din oțel dn.273 este izolata ?
Answer (25 Jun 2024, 11:59):
Analizați, vă rugăm, norma mai atent, tubul de protecție, conform normei, este izolat.
Only authorized platform users may ask questions during the clarification period.
Document successfully signed
OK