Status Cancelled
Estimated value without VAT 1 726 365 MDL
Period of clarifications: 25 Mar 2024, 8:51 - 3 Apr 2024, 11:50
Submission of proposals: 3 Apr 2024, 11:50 - 10 Apr 2024, 9:50

Supplier technical support:

(+373) 79999801


This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.

articole și consumabile medicale specifice secției endoscopie

Information about the cancellation
The reason of cancellation
string
Date of cancellation
27 Mar 2024, 7:41
Information about customer
Fiscal code/IDNO
Address
2025, MOLDOVA, mun.Chişinău, mun.Chişinău, N. Testemiteanu nr.29
Web site
---
The contact person
Full name
Natalia Ţurcanu
Contact phone
022574561
Purchase data
Date created
25 Mar 2024, 8:42
Date modified
27 Mar 2024, 7:41
Achizitii.md ID
21191394
CPV
33140000-3 - Consumabile medicale
Type of procedure
Open tender
Award criteria
The lowest price
Funding sources
List of lots
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Cancelled
Date:
25 Mar 2024, 13:27
Question's name:
Lot 2 Ansa polipectomie rotativa asimetrica (gastro-colono.)
Question:
conector lateral de irigare - acest tip de conector este doar pentru instrumentele de multifolosinta, care la moment, practic nu se mai produc ! - Fir metalic impletit 7-9 fire (la cerere) - cum poate sa fie 7-9 fire, la ce producator este specificat acest lucru ? fiecare producator are o anumita tehnologie de productie, ce trece anumite teste de certificare, poate sa fie cu 1 fir, sau cu mai multe fire. Celea cu un fir sunt mai rigide cu mai multe fire sunt mai moi, in rest nu are nici-o plus valoare specificarea data. Nu am vazut la nici-un producator sa fie specificat numarul de fire impletite ... este un parametru practic imposibil de demonstrat sau aratat !
Date:
25 Mar 2024, 13:32
Question's name:
Lot 4 Forceps endoscopic pentru hemostaza prin coagulare
Question:
- cu conector lateral pentru irigare, rotativ - toate forcepsurile de coagulare sunt la moment de unica folosinta, iar portul de irigare este specific pentru instrumentele reutilizabile si nu exista nici-un producator care sa produca forceps de coagulare de unica folosinta cu canal de irigare. - Lungimea 2000mm (+-5mm) - cine poate sa se incadreze in asa parametri ? de obicei asa lungimi sunt necesare pentru colonoscopii, iar la gastro e 1600-1800mm, dar multi producatori produc cu lungimea de 2300mm pentru colonoscopie sau 1800mm pentru gastro, este doar un parametru limitator.
Date:
25 Mar 2024, 13:34
Question's name:
Lot 10 Cos extracteur de calcul/ Baschet
Question:
- cu port de irigare: portul de irigare este specific pentru instrumentele reutilizabile si nu exista nici-un producator care sa instrumente de unica folosinta cu canal de irigare
Date:
25 Mar 2024, 13:38
Question's name:
Lot 14 Forceps biopsie gastroscop
Question:
-diametrul de 2,4-2,8mm - Acesta este diametrul cateterului, el nu are nici-o valoare la procedura, este important sa fie compatibil cu canalul de biopsie a endoscopului (2.0mm, 2.2mm, 2.8mm, 3.0mm, 3.2mm, 3.7mm, 4.2mm) In rest specificarea de 2.4 - 2.8 nu are nici-o valoare. Daca va fi diametrul cateterului 2.3 sa inteleg ca deja nu va fi acceptat ? -lungimea-160cm, acesta este forceps de biopsie pentru gastroscop, producatorii care produc pentru gastro au cu lungimea de 160-180cm. Mentionarea stricta la 160 este doar o limitare de concurenta !
Date:
25 Mar 2024, 13:42
Question's name:
Lot 19 Papilotom canular biluminar
Question:
- electrod de taere arcat / electrod ac-retractabil 10 mm : Este papilotom arcuat sau papilotom AC ? din descriere nu este clar ce se doreste. - directia taerii-ora 11 - directie este selectata de doctor in timpul operatiei, ce se are in vedere prin acest parametru ?
Date:
25 Mar 2024, 13:43
Question's name:
Lot 20 Papilotom Tip 3
Question:
diametru 4,4-4,5 Fr - care este acest diametru ? Sa fie compatibil cu duodenoscopul ?
Date:
25 Mar 2024, 13:44
Question's name:
Lot 21 Papilotom precut
Question:
biluminar - Daca va fi triplu lumen, va fi acceptat ?
Date:
25 Mar 2024, 13:51
Question's name:
Lot 25 Stent biliar PVC
Question:
Aceste tipuri de stenturi si-ai demonstrat ineficienta si cu foarte multe probleme dupa amplasare. La moment sunt doar niste producatorii indieni/chinezi care le mai produc. Toti producatorii mari sau mici, cu o traditie in aceste produse, au trecut la stenturile de teflon. Revizuiti necesarul si utilitatea acestui tip de produs !!!
Date:
25 Mar 2024, 13:53
Question's name:
Lot 26 Stent biliar metalic(nichel-titanum)-expandabil
Question:
tub de inserție teflon de 175 mm. - daca va fi 170,190, 200 sau 230 nu va fi acceptat ? E din aceeasi categorie de stenturi.
Date:
25 Mar 2024, 13:55
Question's name:
Lot 33 Sondă balon-extractor pentru colangiografie endoscopica
Question:
- lungime 2000: daca va fi 2100 sau 2300 va fi acceptat ? - 5-7Fr: ce este acet parametru ? Puneti mai bine canalul de lucru compatibil nu limitati la niste parametri nesemnificativi.
Date:
25 Mar 2024, 13:57
Question's name:
Lot 39 Capac pentru capatul distal al endoscopului
Question:
- cu 2 orificii pentru irigare: Pentru ce sunt necesare 2 orificii, Este sufiecient 1 orificiu pentru ca sa nu se opreasca lichidul in interior, in rest nu are nici-o importanta. La unii producatori poate sa fie un orificiu mai mare, la altul poate sa fie 2 orificii mai mici, functional au acelasi rezultat !
Date:
25 Mar 2024, 13:59
Question's name:
Lot 46 Forceps biopsie "fierbinte"
Question:
- Diam 2,8-3,7mm : Corect ar fi diametrul canalului de lucru, altfel poate fi confuz. - lungimea nu mai mica de 230 cm: Daca va fi 2000 sau 2100 nu va fi acceptat ?
Date:
25 Mar 2024, 14:04
Question's name:
Lot 51 Set Electroade -pentru dissectie endoscopica
Question:
De ce nu faceti pozitii separate ? Exista doar un producator car ofera asa tip de set ! Totodata nu este rational sa fie set. Puteti avea 4 operatii de disectie la care sa fie necesar doar electrodul patrulater sau drept, dar deoarece aveti 3 seturi si doar 3 buc nu veti avea instrumentele necesare. Nu exista nici-o operatie la care sa fie necesare toti 4 electrozi de utilizat. Pe de alta parte veti eficientiza cel mai bun pret per pozitie !!! Iar in final un set o sa coste mult mai ieftin !