1
Enquiry period
with 05.05.2023 18:27
to 22.05.2023 16:00
2
Bidding period
with 22.05.2023 16:00
to 02.06.2023 13:00
3
Auction
will not be used
4
Evaluation

5
Contract

Status Evaluation
Estimated value without VAT 230 000 MDL
Period of clarifications: 5 May 2023, 18:27 - 22 May 2023, 16:00
Submission of proposals: 22 May 2023, 16:00 - 2 Jun 2023, 13:00

Supplier technical support:

(+373) 79999801


This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.

Echipamente medicale - Ultrasonograf General, portabil

Information about customer
Title
Fiscal code/IDNO
Address
MD-2004, MOLDOVA, mun.Chişinău, locality, mun. Chişinău, sec. Buiucani, str. Ciorbă Toma, 18A
Web site
---
The contact person
Full name
Carp Angela
Contact phone
+37322233568
Purchase data
Date created
5 May 2023, 18:11
Date modified
19 May 2023, 18:23
Achizitii.md ID
21080010
CPV
33100000-1 - Echipamente medicale
Type of procedure
Open tender
Award criteria
The lowest price
Funding sources
List of lots
Documents of the procurement procedure
#171_GDH2_Formular Oferta_Ultrasonograf portabil_052023
Technical Specifications
Formular Oferta_#171/GD/H
5.05.23 18:27
#171_GDH2_ITQ Ultrasonograf portabil PN HIV_052023
Technical Specifications
ITQ_#171/GD/H
5.05.23 18:27
Amendament #1 la ITQ#171GD_H Ultrasonograf portabil 15052023
Technical Specifications
Modificare 1 ITQ #171/GD/H
15.05.23 13:21
#171_GDH2a_ITQ Ultrasonograf portabil PN HIV_15052023
Technical Specifications
ITQ_#171/GD/H_Ajustat
15.05.23 13:21
#171_GDH2a_Formular Oferta_Ultrasonograf portabil_15052023
Technical Specifications
Formular Oferta ajustat_#171/GD/H
15.05.23 13:21
#171_GDH3_Formular Oferta_Ultrasonograf portabil_19052023
Technical Specifications
Actual_Formular oferta #171/GD/H
19.05.23 18:23
#171_GDH3_ITQ Ultrasonograf portabil PN HIV_19052023
Technical Specifications
Actual_ITQ#
19.05.23 18:23
Amendament #2 la ITQ#171GD_H Ultrasonograf portabil 19052023
Technical Specifications
Modificare 2
19.05.23 18:23
LOT I. Ultrasonograf General, portabil:
Date:
12 May 2023, 16:35
Question's name:
Clarificare
Question:
Bună ziua, Rugăm respectuos modificarea resoluției 2736 x 1824 în rezoluție HD 1920x1200, deoarece rezoluția solicitată inițial este susținută doar, de tablete Microsoft Surface Pro 4 (2736 x 1824) Resolution Tablet 6th Generation TOUCH (https://support.microsoft.com/en-us/surface/surface-pro-6-specs-and-features-ade5cfc2-e99a-6fd1-abbe-c0e8a8a3942d), astfel se limitează spectrul de oferte economic avantantajoase. Mulțumim aniticipat.
Answer (15 May 2023, 13:24):
Se accepta modificarea rezoluției 2736 x 1824 în rezoluție HD 1920x1200. Va rugam sa considerati ITQ #171/GD/H2a si Formularul de Oferta #171/GD/H2a din 15/05/2023 in format ajustat conform Amendamen #1, atasate la prezentul anunt.
Date:
15 May 2023, 16:38
Question's name:
Clarificari
Question:
Buna ziua, rugam respectuos sa indicati Coloan vertebrala este necesar sa fie scanata in regim de obstetrica (trimestul 2/3) sau adult??
Answer (19 May 2023, 16:15):
Scanarea coloan vertebrala in regim de obstetrica (trimestul 2/3) sau adult - nu este necesara.
Date:
15 May 2023, 17:28
Question's name:
Clarificari
Question:
Buna ziua, rugam respectuos sa micsorati numarul de canale digitale de la 600.000 la 200.000 este cifra reala pentru toti producatori, mai laes ca este un ecograf de tip portabil nu stationar.
Answer (19 May 2023, 16:17):
Se accepta micsorarea numarului de canale digitale la 200.000 canale, cu ajustare caiet de sarcini dupa cum urmeaz: - ”PREPROCESARE, Canale digitale, procesate simultan ≥ 200 000”
Date:
15 May 2023, 17:41
Question's name:
Clarificari
Question:
Monitorul indicat de 12 inch cu touch screne sau separat de cel central, este prezent oficial doar la un singur producator de renume Mindray ME7 sau ME8. Daca este intentia de a se porcura un astfel de dispoztiv pentru ce se face o licitatie cind restul produatorilor de renume nu se pot incadra cu dispaly sau un canale digitale care sint cu mult depasite fata de un ecograf portabil. Totusi un ecograf portabil este pentru investigati de rutina si nici de cum nu pentru cea finale. Acumulatorul de 10 ore minim la utilizarea obisnuita nu are nici un sens nu sintem in Africa unde lumina este doar 2 ore pe zi. Iar o scanre presupune o activare a 2 regimuri minime B-Mode si cel Color si in unile cazuri Pulsativ in regim vascular, toate avind cosum de energei diferit. Studind in complet toata specificatia rezulta ca este un ecograf compus din parametri de la diferiti producatori care nu se leaga unul de altul sau este sub un anumit producator care nu are un concucrent real. Conform legii Achiziti este necesar de prezenta a minim 3 concurenti reali pentru. Asta ar presune o specificatie tehnica valabila pentru 3 producatori cel putin.
Answer (19 May 2023, 16:55):
La compartementul ”Cerințele & Specificațiile Tehnice minime” din Anexa A la Termenii și condițiile de furnizare, urmatoarele prevederi se modifica si se expun in redactia nouă: - ”MONITOR minim 12", ecran touch screen sau cu panel touch screen integrată în consola sistemului.” se expune in redactia noua: ”Panel touch screen integrată în consola sistemului.” - ”Baterie: mini 10 ore la utilizare obișnuita” se expune in redactia noua: ”Autonomie: minimum 3 ore in lucru ”.