This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.
Subscribe impossible
during the period Evaluation
Aprovizionarea cu apa potaila al locuitorior ,agentilor economici ,intitutiilor satului Bratuleni,raionul Nisporeni
Information about customer
Fiscal code/IDNO
Address
6417, MOLDOVA, Nisporeni, s.Brătuleni, MD 6417 Brătuleni, r-n Nisporeni
Web site
---
The contact person
Purchase data
Date created
14 Sep 2022, 11:02
Date modified
15 Sep 2022, 21:27
Achizitii.md ID
21063634
MTender ID
CPV
45200000-9 - Lucrări de construcţii complete sau parţiale şi lucrări publice
Type of procedure
Open tender
Award criteria
The lowest price
Funding sources
List of lots
Lot nr. 1 - Retelele de apeduct in localitatea Bratuleni,raionul Nisporeni
Budget: 7723404.17 MDL
Active
Documents of the procurement procedure
Date:
15 Sep 2022, 21:27
Question's name:
Corectari in caietul de sarcini
Question:
Consultati va rog proiectul si verificati daca sunt corecte diametrele la pozitiile din caietul de sarcini: Poz. 15, Poz. 29, Poz. 31, deoarece cinform caietului de sarcini teava cu diametre mai mari de Dn-90mm nu avem iar armaturi sunt si la 100mm si la 150mm... Ceva nu se leaga aici.
Answer (17 Sep 2022, 14:03):
Pozitia 29 si pozitia 31 at diametrul DN80
Date:
17 Sep 2022, 16:28
Question's name:
Caiet de sarcini
Question:
poz.2 Care este inaltimea hidrantului ?
Answer (19 Sep 2022, 08:41):
Inaltimea hidrantului 1 metru
Date:
19 Sep 2022, 09:30
Question's name:
Garantie pentru oferta
Question:
Buna ziua, va rugam sa publicati rechizitele bancare
in vederea perfectarii garantiei prin transfer la contul autoritatii contractante,
multumim anticipat.
Answer (20 Sep 2022, 13:51):
MD81TRPCDL518410A01524AA
Date:
20 Sep 2022, 08:54
Question's name:
Caiet de sarcini
Question:
Poz. 2 specificati tipul hidrantului?
Answer (20 Sep 2022, 09:33):
hidrant DN80
Date:
20 Sep 2022, 21:24
Question's name:
Anuntul
Question:
Garantie de buna executie prin garantie bancara nu este prevazuta, de HG 638 , vedeti pct. 153,
Answer (21 Sep 2022, 15:15):
Garantia de buna executie a contractului se va constitui din retineri succesive directe din plata cuvenita pentru facturile inaintate .
Date:
21 Sep 2022, 08:46
Question's name:
tipul hidrantului
Question:
Deci există hidranți subterani și supraterani, DVS de care doriți la poz.2?
Answer (21 Sep 2022, 11:43):
subterani
Date:
22 Sep 2022, 09:47
Question's name:
Caiet de sarcini
Question:
Poz. 64 - explicați Vă rog cum să punem K=0,5 pe preț la pietriș?
Answer (22 Sep 2022, 15:21):
Jumatate din pietris se pune nou,jumatate se pune existent .De asta si se foloseste coeficientul de 0.5 .Manopera este 100 %
Date:
22 Sep 2022, 12:02
Question's name:
Caiet de sarcini
Question:
poz.15 și 16 concretizați Vă rog teava?
Answer (22 Sep 2022, 15:22):
Teava PE100 RC SDR17 PN10 cu strat de protectie din PP si fir cobtinuite din inox
Date:
23 Sep 2022, 18:00
Question's name:
poz.44, 45
Question:
Publicati va rog F1 desfasurata. Nu e clar ce fel de beton pentru opritoare. Se adauga o resura noua? sau se modifica beton existent in norma data?
Answer (24 Sep 2022, 08:44):
Pentru pozitia 44 in betonul pentru camine este inclus si betonul pentru opritoare cu V =1,3mc.betonul este clasa BC7,5/B100 nu se adauga nici o resursa noua.
Pentru pozitia 45 in betonul pentru camine este inlus si betonul pentru opritoare cu V=0,45 mc .betonul este clasa B15/M200 nu se adauga nici o resursa noua.
Only authorized platform users may ask questions during the clarification period.