Estimated value without VAT 9 000 MDL
Period of clarifications: 22 Jan 2020, 14:27 - 24 Jan 2020, 17:00
Submission of proposals: 24 Jan 2020, 17:00 - 28 Jan 2020, 11:00

Supplier technical support:

(+373) 79999801


This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.

Servicii de determinare a calității parametrilor de corespundere și a dozelor primite de pacient în cabinetele radiodiagnostice

Information about customer
Fiscal code/IDNO
Address
MD2004, MOLDOVA, mun.Chişinău, mun.Chişinău, bd. Ștefan cel Mare 165
Web site
---
The contact person
Full name
Natalia Cadelnic
Contact phone
022-205265
Purchase data
Date created
22 Jan 2020, 14:27
Date modified
23 Jan 2020, 16:36
Achizitii.md ID
21018383
CPV
50400000-9 - Servicii de reparare şi de întreţinere a echipamentului medical şi de precizie
Type of procedure
Low cost purchase
Award criteria
The lowest price
Funding sources
Documents of the procurement procedure
anunt de participare.docx
tenderNotice
anunt de participare
22.01.20 14:27
Date:
23 Jan 2020, 16:36
Question's name:
specificatii tehnice
Question:
Rugăm să indicați lista utilajului ce necesită a fi testat (cantitatea și tipul), cu indicarea pentru fiecare unitate a listei de investigații inclusiv parametrii radiologici (kV, mAs, timp expunere) pentru determincarea dozei primite de pacient pe fiecare investigație. Mulțumim anticipat.
Answer (24 Jan 2020, 12:32):
Clinica 1 Ortopantomograf PLANMECA PRO ONE PTH100188 ; anul fabricarii: 2010 Clinica 1 Viziograf MAX70HF/DC T5P534 ; anul fabricarii: 2010 Clinica 2 Tomograf PLANMECA PROMAX KPP4000340; anul fabricarii: 2010 Clinica 2 Viziograf ERGON –X 70AC 100640; anul fabricarii: 2010. 1. Viziograf MAX 70 HF/DC: generator model TB3V3; producător: CSN Industrie – Italy; S/N E7P545; Nr. inr. ANRAN – A; anul producție – 2012; Cîmp max iradiere: 6 cm.; Distanța focala SID 20cm.; Puterea nominală -0.8 kW; Tip generator AC/DC – DC; Tensiune anod kVp – 70 kVp; Curent anod mA – 6 mA; Timp expunere sec – 0.04 -3.2; Timp preîncălzire msec; Date despre tub/ montank – TB3V3; Model cupola/insert – TB3V3/ D-0811; S/N cupola/insert – T5P534/2C89507; Producător: Italy/Japan; Nr.Inr. ANRAN G; anul producție – 2012; Dimensiuni focar 0.6mm; Tensiune anod max – 70kV; Curent anod max – 6 mA; filtru inst./HVL total 2/0.6; Tipul RaySafe X2; Unitatea de bază S/N – RaySafe S/N 8251010; Sensor tip, S/N, calibrare X2 R/F Sensor, S/N 218131, cal 16-01-29. 2. Ortopantomograf Planmeca ProOne: generator model ProOne; producător: Planmeca Finlanda; S/N PTH100188; Nr. inr. ANRAN – A; anul producție – 2010; Cîmp max iradiere: 14 cm./30cm.; Distanța focala SID 48cm.; Puterea nominală -0.85 kW; Tip generator AC/DC – DC; Tensiune anod kVp – 60kV/70 kV; Curent anod mA – 2 mA/7mA; Timp expunere sec – 2 sec/ 10 sec; Timp preîncălzire msec; Date despre tub/ montank – D-058SB; Model cupola/insert – D-058SB; S/N cupola/insert – PTH100188/9C05659; Producător: TOSHIBA; Nr.Inr. ANRAN G; anul producție – 2010; Dimensiuni focar 0.5mm; Tensiune anod max – 70kV; Curent anod max – 7 mA; Filtru inst./HVL total 2.5mmAl; Aparate utilizate: Tipul RaySafe X2; Unitatea de bază S/N – RaySafe S/N 8251010; Sensor tip, S/N, calibrare X2 CT Sensor, S/N 217454, 05-02-16 R/F Sensor S/N 218131,01-29-16. Dacă apar careva neclarități reveniți la nr.tel:022 205 267
Only authorized platform users may ask questions during the clarification period.